national instruments scxi 1166. Refer to the NI Switches Getting Started Guide to determine when to install the terminal block. national instruments scxi 1166

 
 Refer to the NI Switches Getting Started Guide to determine when to install the terminal blocknational instruments scxi 1166 National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) Series modules for the National Instruments data acquisition plug-in boards

For additional information on driver support, refer to Software Support for CompactRIO, CompactDAQ, Single-Board RIO, R Series, and EtherCAT . NI-SWITCH 16. NI-DAQmx 18. 0 : Windows 10/8. their associated screw terminals. NET 4. Each channel has three terminals—common32-Channel, General-Purpose Switch Module for SCXI32-Channel, General-Purpose Switch Module for SCXI我上一个项目是通过 labview 做的,但从下一个项目开始。 我需要通过cvi来完成。在我的工程中需要用到以下ni仪器, 所用到的. NI-DAQmx 17. Microsoft Windows 7、Windows Vista、Windows XP和Windows Server 2003的NI软件支持プログラムと機能 をダブルクリックします。. NI SCXI-1166 32-SPDT relay module; NI SCXI-1167 64-channel relay driver; NI SCXI-1169 100-channel SPST relay module; NI SCXI-1190 1. Third-Party Accessory for the NI SCXI-1166 Accessory Manufacturer 62-pin D-SUB connector, female, solder cup Any channel a single SPDT (form C) relay. Rechtliche Hinweise. The toolbox supports NI-SWITCH devices using the NI-SWITCH driver version 4. 지원되는 OS. 저작권 2003–2006 National Instruments. 1은 다음 OS를 지원합니다. アンインストールと変更 ボタンをクリックします。. NET Framework 2. 2. From the Functions palette, select Measurement I/O»NI-SWITCH to access the NI. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. Refer to the NI Switches Help, accessible from Start»All Programs»National Instruments. NI-DAQmx 16. PXI-2566: 16. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. The following operating systems are supported by NI-DAQmx 17. NI SCXI-1331 Installation Instructions 8 ni. 지원되는 OS. NI-DAQmx 14. Puede utilizar también CompactDAQ, USB Sleeve, ó plataformas SCXI. The NI SCXI-1366 (Part Number: 777687-66) is designed to be installed on the front of the SCXI-1166 Switch Module and is meant for general-purpose switching applications. Connect the terminal block to the. Your NI SCXI switch module ships. The following operating systems are supported by NI-DAQmx 17. 2。. ni scxi-1166; ni scxi-1167; ni scxi-1169; ni scxi-1175; ni scxi-1190; ni scxi-1191; ni scxi-1192; ni scxi-1193; ni scxi-1194; ni scxi-1195; ni scxi-1314t; ni scxi-1502; ni scxi-1503; ni scxi-1520; ni scxi-1521/b; ni scxi-1530; ni scxi-1531; ni scxi-1540; ni scxi-1581; ni scxi-1600 (windows 8. AT times, switches 0 to 15 work but 16 to 31 do not. 1 arbeitet mit folgenden Betriebssystemen: Windows 10 (32 und 64 Bit) Windows 8. 6. National Instruments Keywords "SCXI-1166, letter of. ≥10 MHz Crosstalk (50 Ω system, typical at 23 °C) Channel-to-channel, with NI SCXI-13661 10 kHz. 1. NI-DAQmx 15. 5自述文件. NI-DAQmx 17. Find the National Instruments SCXI-1166 at our website: Click HERE. 1 addresses issues with NI-XNET modules on Ethernet and wireless CompactDAQ chassis not loading properly. 8 or higher. 本文件包含NI-DAQmx的重要信息,包括安装指南和已知问题。NI-DAQmx 16. NI-SWITCH is an interchangeable virtual instrument (IVI)–compliant. 1은 다음 OS를 지원합니다. 1 1 /7 SP1 2 (32-bit and 64-bit) Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers) Windows Server 2012 R2 1 (64-bit) Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role) 1 NI software installs VC2015 Runtime and . 新增功能. 1 also fixes issues with PXIe-4303 and PXIe-4339 devices showing incorrect data when changing the. The SCXI-1160 has 16 independent SPDT (Form C) latching relays with very low on-resistance and low thermal. This unit is sealed in the original manufacturer's static bag. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。 NI-488. 32-Channel, General-Purpose Switch Module for SCXII am using PXI-4060 DMM to communicate with my SCXI-1001,but the MAX can not recongnize the SCXI-1166 correctly?How to solve this problem? Return to Home Page Toggle navigation32-Channel, General-Purpose Switch Module for SCXINI-SWITCH 4. システム要件. 0 adds support for LabVIEW 2016. 6. 1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI. 778720-01 Cable and Wire from NATIONAL INSTRUMENTS 2-Year Warranty - CUSTOM CABLE KIT, SWITCH MODULE, ACCESSORY TYPE:CUSTOM CABLE KIT, FOR USE WITH:NI PXI-2566 RELAY MODULES & SCXI-1166 GENERAL PURPOSE SWITCH MODULES,. 6. Please call or email us with your request. Lizenzverträge von National Instruments und Rechtshinweise von Drittanbietern. NI Switches SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. NI-DAQmx 14. Each channel includes a frequency‑to‑voltage conversion circuit with programmable input range, threshold, hysteresis, and filtering. NI-DAQmx支持的设备. When I first power up the external SCXI chassis, I can run through my tests without a hitch. このファイルには、インストール手順、既知の問題など、NI-DAQmxに関する重要な情報が記載されています。. 5. 1 arbeitet mit folgenden Betriebssystemen: Windows 10 (32 und 64 Bit) Windows 8. for the NI SCXI-1166. If you will also use the SCXI-1180 feedthrough panel, the SCXI-1343 rear screw terminal adapter, or the SCXI-1351 one-slot cable extender with the SCXI-1161, read. Refer to the NI Switches Getting Started Guide to determine when to install the terminal block. 0. 본 페이지는 SCXI-1166 의 치수도면을 제공합니다. AXICOM (Tyco Electronics) IM42GR (3-1462037-1) Relay. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100This page provides dimensional drawings for the SCXI-1166. 1 1 (32 und 64 Bit); Windows 7 SP1 2 (32 und 64 Bit); Windows Embedded Standard 7 2, SP1 (32 und 64 Bit); Windows Server 2012 R2 1 (64 Bit); Windows Server 2008 R2 1, SP1 (64 Bit, nicht auf Server Core Role unterstützt); 1. Lizenzverträge (EULAs) von National Instruments. 1 also fixes issues with PXIe-4303 and PXIe-4339 devices showing incorrect data when changing the. 0: Windows 10/8. This document contains information about the NI-DAQmx driver software, which you canOrder by Part Number or Request a Quote. Les systèmes d'exploitation suivants sont supportés par NI-DAQmx 17. National Instruments ofrece tres maneras de llevar a cabo la conmutación (Switching) y el uso de multiplexores (Muxing) en USB. Lizenzverträge (EULAs) von National Instruments. The SCXI-1166 can switch up to 2A at 30 VAC/30 VDC and can carry 5A per channel. The switch modules that can connect with a SCXI-1357 are: SCXI-1127; SCXI-1128; SCXI-1129; SCXI-1130; SCXI-1175; SCXI-1166; SCXI-1167; SCXI-1169; SCXI-1193; SCXI-1194; SCXI-1195; The key component is the auxiliary cable which connects the AUX I/O port of the DMM to the AUX I/O port of the SCXI-1357 backplane connector. SCXI™ Getting Started with SCXI. 1 : Windows 10/8. Manufacturer: National Instruments Board Assembly Part Numbers (Refer to Procedure 1 for identification procedure): Part Number and Revision Description 189266A-01 or later SCXI-1166 General Purpose Switch Volatile Memory Target Data. NI SCXI-1166 32-SPDT relay module; NI SCXI-1167 64-channel relay driver; NI SCXI-1169 100-channel SPST relay module; NI SCXI-1175 196x1 relay multiplexer;The National Instruments SCXI-1166 is a general purpose 32-channel switch modules. The following operating systems are supported by NI-DAQmx 17. NI-DAQmx 15. SCXI-1166 SCXI-1366 Screw terminal for 32 relays 777687-66 Backshell connector kit for custom cable (requires two) 778720-01 PXI-2501, TB-2605 Multiplexer 777878-01. NI-DAQmxは、NIデータ収集(DAQ)デバイスとの通信と制御を行うために使用するソフトウェアです。 NI-DAQmx Readmeの更新daq 入门指南 2ni. Accessories Available for the NI SCXI-1166 Accessory Part Number NI SCXI-1366 terminal block 777687-66 Backshell and connector kit 778720-01 Table 2. 1 : Windows 10 (32 et 64 bits) Windows 8. Verify the Components. このファイルには、インストール手順、既知の問題など、NI-DAQmxに関する重要な情報が記載されています。. This page provides dimensional drawings for the SCXI-1166. NIソフトウェアをMicrosoft Windows 8. This document explains how to install and configure SCXI signal conditioning modules in SCXI-1000, SCXI-1001, SCXI-1000DC, or PXI/SCXI combination chassis, confirm the. 1 and later. Operating System Support. 系统要求. Is this just because you can designate two DPDT relays to act simultaneously? As the subject indicates I’m looking at the SCXI-1166 or PXI-2570 boards. Introduction The SCXI-1366 terminal block installs in front of the SCXI-1166 switch module and has screw terminals that pr ovide access to each of the 32 relays. 32-Channel, General-Purpose Switch Module for SCXINational Instruments SCXI-1366 te rminal block. 驱动程序版本名称变化. Refer to the NI Switches Getting Started Guide to determine when to install the terminal block. Lizenzverträge von National Instruments und Rechtshinweise von Drittanbietern. Introduction The SCXI-1366 terminal block installs in front of the SCXI-1166 switch module and has screw terminals that pr ovide access to each of the 32 relays. The optical isolation of the SCXI‑1162 eliminates ground-loop. This page provides dimensional drawings for the SCXI-1166. NI SCXI-1166 Specifications 4 ni. 1 1 (32-bit and 64-bit); Windows 7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2, SP1 (32-bit and 64-bit); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on. 1 1 /7 SP1 2 (32-bit and 64-bit 3); Windows Embedded Standard 7 2, SP1 (on Compact DAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on Server Core Role); 1 NI. These relays are suitable for switching, routing, and controlling medium-level signals. Click the Chassis tab. 3 GHz quad 4x1 50 ohm multiplexer; NI SCXI-1191 4 GHz quad 4x1 50 ohm multiplexer; NI SCXI-1192 18 GHz 8-SPDT 50 ohm relay module; NI SCXI-1193 quad 8x1 50 ohm multiplexer The National Instruments SCXI-1166 is a general purpose 32-channel switch modules. 2: Windows 8. SCXI-1163R; SCXI-1167; SCXI-1192;Supported Operating Systems. 또한 NI-DAQmx 15. 系统要求. 32-Channel, General-Purpose Switch Module for SCXI—The SCXI‑1166 is a general-purpose switching module with independent single‑pole double‑throw (SPDT), also called Form C, latching relays with very low on-resistance and low thermal offset. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. 2015年10月版. The NI SCXI-1166 (Part Number: 776572-66) has 32 channels, non-latching relays, is completely software programmable, and a maximum cycle speed of 115 operations per. 2를 설치합니다. NI PXI-2566 ; NI PXI-2593 ; NI SCXI-1166 ; NI SCXI-1193 . ここでは、修正された問題をすべて網羅しているわけでは. ni scxi-1163; ni scxi-1163r ; ni scxi-1166; ni scxi-1167; ni scxi-1169; ni scxi-1175; ni scxi-1190; ni scxi-1191; ni scxi-1192; ni scxi-1193; ni scxi-1194; ni scxi. SCXI device can create a shock or fire hazard, or can damage any or all of the boards connected to the SCXI chassis, the host computer, and the SCXI device. NI-SWITCH 4. All specifications are subject to change without notice. This page provides dimensional drawings for the SCXI-1166. 32-Channel, General-Purpose Switch Module for SCXINI SCXI-1166; NI SCXI-1167; NI SCXI-1169; NI SCXI-1175; NI SCXI-1190; NI SCXI-1191; NI SCXI-1192; NI SCXI-1193; NI SCXI-1194; NI SCXI-1195; NI SCXI-1314T; NI SCXI-1502; NI SCXI-1503; NI SCXI-1520;. NI-DAQ 8. x/7/Vista: NI DAQCard-6024E 200 kS/s, 12-bit, 16 analog input channel, two analog output channel, 8. ≤–75 dB 100 kHz. • Male to Female 78-Pin D-Sub Connector. Si vous n'utilisez pas de logiciel d'application, reportez-vous à la section Support de Microsoft Visual Studio. Windows 10/8. Ensure the cable between SCXI chassis and DAQ devices is propperly connected or try another else cable assembly. Page 1 SCXI-1120/D, SCXI-1121, SCXI-1125, and SCXI-1126 to 42 V or DC. . 1 includes the following new features: Support for the NI PXI/PXIe-2540 and NI PXI/PXIe-2541 modules. NI 9226: 8. 2를 설치합니다. 1 addresses issues with NI-XNET modules on Ethernet and wireless CompactDAQ chassis not loading properly. NI-DAQmx 14. Introduction The SCXI-1366 terminal block installs in front of the SCXI-1166 switch module and has screw terminals that pr ovide access to each of the 32 relays. 1. National Instruments SCXI-1167 64-Channel External Relay Driver. 2. NI-DAQmx 15. 1. Also for: Scxi-1305. NIソフトウェアをMicrosoft Windows 8. 0新增对LabVIEW 2018和LabVIEW NXG 2. 自动安装NI产品的方法. 产品安全及关键更新. Rechtliche Hinweise. 저작권법상 이러한 출판물은 National Instruments Corporation의 서면에 의한 사전 동의 없이는 그 일부나 전부를 사진 복사, 녹음, 정보 검색 시스템에 저장하는 것, 번역 등을 포함하여 전자적이거나 기계적인 방법을 막론하고 어떠한 방법이나. CompactDAQ: Ofrecemos dos módulos de relevadores para la plataforma CompactDAQ: él NI 9181 y él NI 9185. Supported Hardware. National Instruments SCXI-1166 Installation Manual (9 pages) Brand: National Instruments | Category: Terminal Block | Size: 1. The following operating systems are supported in NI. NI-VISA. NI SCXI-1166 (Modul mit 32 Umschaltrelais) NI SCXI-1167 (Relais-Treiber mit 64 Kanälen) NI SCXI-1169 (Modul mit 100 einpoligen Einschaltrelais). 63 MB. The NI PXI-2569 uses electromechanical armature relays. NI SCXI-1166; NI SCXI-1167; NI SCXI-1169; NI SCXI-1175; NI SCXI-1190; NI SCXI-1191; NI SCXI-1192; NI SCXI-1193; NI SCXI-1194; NI SCXI-1195; NI SCXI-1314T; NI SCXI-1502; NI SCXI-1503;. Windows 10/8. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. SCXI-1127. 1 1 (32 et 64 bits); Windows 7, SP1 2 (32 et 64 bits); Windows Embedded Standard 7 2, SP1 (32 et 64 bits); Windows Server 2012 R2 1 (64 bits); Windows Server 2008 R2 1, SP1 (64 bits, non supporté par Server. NI-DAQ 7. NI-DAQmx Readme 업데이트. Featured with a 16-bit ADC, the NI SCXI-1600 (Part Number: 776572-1600) is a USB Data Acquisition Module (DAQ) for SCXI. SCXI-1128. Änderungen an der Readme zu NI-DAQmx. NI SCXI-1166 32-SPDT Topology. 1 1 /7 SP1 2 (32비트 3 및 64비트); Windows Embedded Standard 7 2 SP1 (CompactDAQ 컨트롤러에서); Windows Server 2012 R2 1 (64비트); Windows Server 2008 R2 1 SP1 (64비트, Server Core Role에서 지원되지 않음); 1 NI 소프트웨어가 VC2015 Runtime 및 . NI-VISA. 1 1 /7 SP1 2 (32 und 64 Bit); Windows Embedded Standard 7 2 SP1 (auf CompactDAQ-Controllern); Windows Server 2012 R2 1 (64 Bit); Windows Server 2008 R2 1 SP1 (64 Bit, auf Server Core Role nicht unterstützt); 1 Zusammen mit NI-Software. 5. This page provides dimensional drawings for the SCXI-1166. New initialization, scanning, trigger routing, and relay control functions Support for the NI SCXI-1166/1193 and NI PXI-2566/2593 switch modulesThe help can be launched from Start»All Programs»National Instruments»NI-DAQ». Ambos están controlados por medio. NI-DAQmx 16. NI-DAQmx 17. 2。 Windows 8. Systèmes d'exploitation supportés. 1和Windows Server 2012 R2需要Microsoft更新才能支持这些项。. 0. The second type of National Instruments SCXI Switch is general-purpose switch modules. 应用软件支持. Using NI Software with Microsoft Windows 8. Supported Operating Systems. 1 arbeitet mit folgenden Betriebssystemen:NI SCXI-1166; NI SCXI-1167; NI SCXI-1169; NI SCXI-1175; NI SCXI-1190; NI SCXI-1191; NI SCXI-1192; NI SCXI-1193; NI SCXI-1194; NI SCXI-1195; previous page start next page. 018703 × 10– 7 RT = resistance of the thermistor in ohms VTEMPOUT = output voltage of the temperature sensor where T(°F). They. Connect the DAQ device to a different computer or PXI controller slot, module or USB port. National Instruments offers switches with scanning capabilities. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. x/7/vista의 64비트 버전에서 지원되지 않음)NI-SWITCH 4. To develop an NI-SWITCH application in LabVIEW, follow these general steps: Open a new or existing LabVIEW virtual instrument (VI). Hence, this switch module is ideal for. 1 1 /7 SP1 2 (32-bit and 64-bit 3); Windows Embedded Standard 7 2, SP1 (on Compact DAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on Server Core Role); 1 NI. NET 4. NI-DAQmx supports the following new devices: NI PXI-4204 ; NI PXI-4220 ; NI PCI-6722 device; NI PCI-6723 device; NI PCI-6624 industrial 8-channel CH/CH isolated counter/timer device;SCXI-1166: 32. Systèmes d'exploitation supportés. NI-SWITCH 18. 在Microsoft Windows 10中. 0 adds support for LabVIEW 2015 (32- and 64-bit). Page 1 SCXI -1314T TEDS Bridge Sensor ™ Terminal Block This guide describes how to install and use the SCXI-1314T terminal block with the SCXI-1520 module and hardware Transducer Electronic Data Sheet (TEDS)-enabled bridge sensors (IEEE-P1451. NI-DAQmx 15. 6. This switch module has independent SPDT (Form C) nonlatching electromechanical relays with very low on-resistance and low thermal offsets. 32-Channel, General-Purpose Switch Module for SCXIPlaca SCXI de comutação de uso geral, 32 canaisSupported Operating Systems. 32-Channel, General-Purpose Switch Module for SCXI The NI SCXI-1166 is a 32-channel, general-purpose switch module for the SCXI platform designed for switching and controlling power signals. The following cables control or trigger SCXI switches and can connect to an SCXI backplane adapter:下表列出了NI-DAQmx 16. 3 includes the following new features: Support for the NI PXI-2530B and NI PXI-2571 modules. Each channel includes a frequency‑to‑voltage conversion circuit with. The National Instruments SCXI Series Cables/Adapters connects DAQ devices to SCXI systems. OS 지원. 1: Windows 10/8. Introduction The SCXI-1366 terminal block installs in front of the SCXI-1166 switch module and has screw terminals that pr ovide access to each of the 32 relays. 32-Channel, General-Purpose Switch Module for SCXI I am using PXI-4060 DMM to communicate with my SCXI-1001,but the MAX can not recongnize the SCXI-1166 correctly?How to solve this problem? Return to Home Page Toggle navigation 32-Channel, General-Purpose Switch Module for SCXI NI-SWITCH 4. 288. Backshell and Connector Kit for use with NI PXI-2566 & SCXI-1166. com SCXI Chassis 1. DAQExpressに関する注意事項. The SCXI-1102 also can acquire millivolt, volt, 0 to 20 mA, and 4 to 20 mA current input signals,as well as signals from RTDs when the SCXI-1581 provides excitation. NI SCXI -1366 terminal block pdf manual download. 1 addresses an issue in which incorrect data is returned by multi-device tasks run on the NI cDAQ-9179 with specific module configurations. 5. SCXI-1166 寸法図 2D. 5는 다음 OS를 지원합니다: Windows 10 (32비트. 0 Readme. Each channel has three terminals—commonNational Instruments SCXI-1366 te rminal block. NI 2813. . 2를 설치합니다. 6. 0 : Windows 10 (32 et 64 bits) Windows 8. The controller, the cabling scheme, and the SCXI switches dictate the scanning capabilities. NI-DAQmx supports the. 2를. Some Devices Enumerate Twice. NI-SWITCH 4. 0. You can control the channels using the niSwitch Connect Channels VI or the niSwitch_Connect function. NIソフトウェアをMicrosoft Windows 10と使用する. The SCXI-1104/C modules are members of the National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) Series that are designed for use with National Instruments data acquisition (DAQ) devices. 1解决了USB DAQ设备、CompactDAQ控制器和NI PXIe-4339存在的一些问题。详细信息,见问题修正一节。 自述文件更新. 系统要求. The following table lists the latest DAQ driver that works with various National Instruments SCXI DAQ devices. 018703 × 10–7, and R T = resistance of the thermistor in ohms, where V TEMPOUT is the output voltage of the temperature sensor, where T(°F). Introduction The SCXI-1366 terminal block installs in front of the SCXI-1166 switch2015年3月版. Lizenzverträge (EULAs) von National Instruments. Supported Operating Systems. 1 1 /7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI software installs. The SCXI‑1167 can also drive small DC motors or other inductive. 0. ni scxi-1166; ni scxi-1167; ni scxi-1169; ni scxi-1175; ni scxi-1190; ni scxi-1191; ni scxi-1192; ni scxi-1193; ni scxi-1194; ni scxi-1195; ni scxi-1314t; ni scxi-1502; ni scxi-1503; ni scxi-1520; ni scxi-1521/b; ni scxi-1530; ni scxi-1531; ni scxi-1540; ni scxi-1581; ni scxi-1600 (windows 8. SCXI-1166 March 2017 Notice: This document is subject to change without notice. 0支持下列操作系统: Windows 10/8. Accessories Available for the NI SCXI-1166 Accessory Part Number NI SCXI-1366 terminal block 777687-66 Backshell and connector kit 778720-01 Table 2. 0 adds support for LabVIEW 2014 (32-bit) and LabVIEW 2014 (64-bit). Touch any metal part of the chassis to discharge static electricity. HV8 to HV8 Cable Figure 10. Refer to the NI Switches Getting Started Guide to determine when to install the terminal block. Introduction The SCXI-1366 terminal block installs in front of the SCXI-1166 switch module and has screw terminals that pr ovide access to each of the 32 relays. Introduction The SCXI-1366 terminal block installs in front of the SCXI-1166 switch module and has screw terminals that pr ovide access to each of the 32 relays. 2016年起NI-DAQmx将不再支持Microsoft Windows Vista、Windows XP和Windows Server 2003. National Instruments SCXI is a high-performance signal conditioning and switching platform for measurement and automation systems. Lizenzverträge (EULAs) von National Instruments. Les systèmes d'exploitation suivants sont supportés par NI-DAQmx 16. référer, selon le cas : à la rubrique Aide»Brevets de votre logiciel, au fichier patents. The NI SCXI-1166 (Part Number: 776572-66) has 32 channels, non-latching relays, is completely software programmable, and a maximum cycle speed of 115 operations per second. Refer to the NI Switches Getting Started Guide to determine when to install the terminal block. A valid service agreement may be required. 0 Help. NI-DAQmx自述文件更新. The voltage setting on back side of the chassis should be set to 120V AC. These channels are multiplexed into a. NI-DAQmx 15. The following operating systems are supported in NI-DAQmx 16. National Instruments SCXI-1160 16-Channel General-Purpose Relay Module. The National Instruments SCXI-1102 and SCXI-1112 are designed for high-accuracy thermocouple measurements. NET 4. Application Software 1 Versions Supported by NI-DAQmx 18. NI-DAQmx 14. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. This document contains information about the NI-DAQmx driver software, which you canThe NI PXI-2567 and SCXI-1167 are designed to be 64-channel, multipurpose relay drive modules, capable of driving many types of external relays. 2016年8月. Ensure the modules are setup properly in the Modules tab to match the physical configuration of the chassis. Windows Embedded Standard 7 、SP1(CompactDAQコントローラ上). 3. . The SCXI-1166 can switch up to 2A at 30 VAC/30 VDC and can carry 5A per channel. NET 4. Figure 6. National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) Series modules for the National Instruments data acquisition plug-in boards. 0. 在Microsoft Windows 8. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. Systèmes d'exploitation supportés. 1 includes the following new features: Support for the NI PXI/PXIe-2540 and NI PXI/PXIe-2541 modules. When controlling an SCXI switch with an NI 4021, use a measurement device, such as an NI DMM, to trigger the switch. 6で修正された一部の問題のIDとタイトルです。. This module can switch 2 A at 30 VAC/30 VDC maximum and can carry 5 A for each channel. 0及后续版本无法在不支持的操作系统上安装或运行。. 5500. The following figure represents the NI SCXI-1166 in the 32-SPDT topology. Future releases of NI-DAQ will support additional devices in NI-DAQmx that are currently supported only in Traditional NI-DAQ. Order international: +1 609. This module is a full-featured control and data. SCXI device. 製品をアンインストールするには 削除 を. ©National Instruments Corporation 3 SCXI-1317 Terminal Block Installation Guide Quarter-Bridge 2- and 3-Wire Strain-Gauge Circuits Note Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers or connecting or disconnecting any signal wires. 1 1 /7 SP1 2 (32 und 64 Bit); Windows Embedded Standard 7 2 SP1 (auf CompactDAQ-Controllern); Windows Server 2012 R2 1 (64 Bit); Windows Server 2008 R2 1 SP1 (64 Bit, auf Server Core Role nicht unterstützt); 1 Zusammen mit NI-Software. 이 파일에는 설치 설명 및 알려진 유의사항을 비롯한 NI-DAQmx에 대한 중요한 정보가 포함되어 있습니다. 操作系统支持. Third-Party Accessory for the NI SCXI-1166 Accessory Manufacturer 62-pin D-SUB connector, female, solder cup Any channel a single SPDT (form C) relay. 1中使用NI软件的方法. I noticed that none of the general relay boards have DPDT switches. driver for ni switching instruments national instruments switching instruments supported models: ni 2810, ni 2811, ni 2812, ni 2813, ni 2814, ni 2815, ni 2816, ni 2817, ni 2833, ni 2834, ni pxi-2501, ni pxi-2503, ni pxi-2510, ni pxi/pxie-2512, ni pxi/pxie-2514, ni pxi/pxie-2515, ni pxi-2520, ni pxi-2521, ni pxi-2522, ni pxi-2523, ni pxi/pxie-2527, ni pxi/pxie-2529, ni pxi-2530, ni pxi-2530b. 6: Windows 10/8. Part Number: 189771B-01, 776572-67, 189771A-01. NI-DAQmx is the software you use to communicate with and control your NI data acquisition (DAQ) device. Then, follow the steps below: 1. Once your test data is in MATLAB, you can analyze and visualize that data for tasks such as signal processing, statistical analysis, digital filtering, and curve fitting. 0 adds support for LabVIEW 2016. Hence, this switch module is ideal for. The second type of National Instruments SCXI Switch is general-purpose switch modules. Supported Operating Systems. National Instruments SCXI-1129 with electromechanical relays. Please click here for the latest release of NI-DAQmx. The following operating systems are supported by NI-DAQmx 17. 지원되는 OS. Complies with the essential requirements of. 以下は、NI-DAQmx 17. 6. Lizenzverträge (EULAs) von National Instruments. The SCXI-1166 can switch up to 2A at 30 VAC/30 VDC and can carry 5A per channel. NI-SCXI-1166 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, MATRIX/MULTIPLAYER.