molecular devices 96 well plate reader. Resipher 96x Starter Kit for use with 96-well plates Includes: (1) Resipher Data Hub, (1) Resipher 96x Reader, (3) sterile sensing lids, all cables Turns a 96-well plate into a precise dynamic oxygen consumption reader, measures 96 wells Utilizes Lucid Lab Cloud software for connection to any…. molecular devices 96 well plate reader

 
 Resipher 96x Starter Kit for use with 96-well plates Includes: (1) Resipher Data Hub, (1) Resipher 96x Reader, (3) sterile sensing lids, all cables Turns a 96-well plate into a precise dynamic oxygen consumption reader, measures 96 wells Utilizes Lucid Lab Cloud software for connection to any…molecular devices 96 well plate reader  High-throughput, automated dynamic light scattering

A microplate adapter is required in the reading chamber drawer for 96- and 384-well assay plates. Can read 96 well plates (optional 384 well). 96-well Molecular Devices P/N 42-000-0117 HE™ High Efficiency microplates, 384-well Molecular Devices P/N 0200-5201. 5 pM Luminescence performance Wavelength range 300–850 nm Wavelength selection Choice of simultaneous detection of all wavelengths or selection in 1. Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. The instrument reads any standard cuvette, microcuvette, test tube and 96 well or UV transparent microplate over full 190-1000 nm wavelength range. Washers configured for both 96- and 384-well plates. x. 5 ng per well. What plates do you recommend for SpectraMax Plate Readers? Luminescence: Solid white plates for top reads and white plates with clear bottoms for bottom reads. 5in (46. Back plate and…. Microplate optimization and read height optimization were performed for best results. VMax . Top or bottom detection is available with a simple click of a button. This is equivalent to having 511 built-in filters,The instruments offer 96- and 384-well microplate-to-microplate fluid transfer (8 or 16 wells at a time), and can read microplates having 6, 12, 24, 48, 96, and 384-well formats. The plate reader optics are tunable for. #CA961) Methods. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Max, FlexStation, Gemini, and earlier instruments as well as import and analysis of data files from FLIPR and Analyst instruments. Step 2: Add sample to well – antigen within the sample binds to the capture antibody. This SpectraMax Plus comes from a long history of reliable tools built by Molecular Devices. Features of Clear 96-Well Microplates: • Clear plates for colorimetric ELISA and other assays. Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. 0 . (Molecular Devices cat. Absorbance was then determined at 450 nm by SpectraMax Paradigm microplate reader (Molecular. The MultiWash+™ Microplate Washer is an automated, compact, quiet, efficient washer with 20 different wash protocol options. Cell line development teams will realize savings on time and resources, as well as faster time-to-market by utilizing a single technology for measuring a critical quality attribute duringOpening the Drawer Manually on page The SpectraMax ABS can accommodate standard 96-well plates. Detection modalities include absorbance (UV-Vis Abs), fluorescence intensity (FI), luminescence (Lumi), and all have. Fluorescence Microplate Reader Comparison Chart. Opaque-walled 96- or 384-well tissue culture plates are available as white or black with solid bottoms and white or black with clear bottoms. View Product. 96/384-well plate formats. Janet got excellent results using them and they are only ~$1. 3% in white 96- and 384-well microplates < 3 x 10-5 (white plates) < 3 x. M2. After incubation of the cells with compounds, add 100 µL (for 96-well plates) or 25 µL (for 384-well plates) of Dye Solution per test well. sdale innersh Triangle Woingham ershire RG41 T United Kingdom 11 umolde. The ThermoMax performs automatic mixing before a reading and between readings to ensure reliable and precise. When a. Sample by eye within . External Dimensions without lid (mm). What is the dead volume in 96 and 384 well compound plates? Dead volume is 5 micro liters. White plates reflect the light, enabling even low levels of Luminescence to be detected. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 nm - 850 nm). The UV-Plate is compatible with the following plate readers: Bio-Tek PowerWave™ 200 Bio-Tek µQuant™ BioRad UltraMark™ Molecular Devices SPECTRAmax® 190, 250, 340PC, and Plus Ordering Information Cat. x. Description: Enter plate name (optional)(2) Wild‑type KRAS inhibits the migration and invasion of pancreatic cancer through the Wnt/β‑catenin pathway Molecular medicine reports January 1, 2023 Hu X, Zhang R, Yao J, Mu B, Zhao C. D SpectraMax® M2 SpectraMax® M2e Multimode Plate Readers User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0102 Rev. 45 µm PVDF. 96-well clear LAL Reagent Grade™ Multi-well Plates (Lonza cat. Published Dec 16, 2020 | Updated Dec 16, 2020. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. Meanwhile, Cowan discusses the importance of considering plate well densities and the angle from which microplates are read inside the reader: “You should definitely check the range of plate well densities supported by your candidate readers. 96-well plates - Filter plates with 0. is required for optimum performa nce with standard 96-well and 384-well format microplates for all top-read applications. The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence polarization (FP) read modesRobust, high-value microplate readers that can run. wells across each plate • Enables viewing and tracking of every well in every plate • Reveals additional information on cellular. Gemini XPS and EM Microplate Readers with dual monochromator fluorometers provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. 4D-Nucleofector 96-well Shuttle: RATE CONTROLLED. Supplier: Molecular Devices Next generation SpectraMax® absorbance microplate readers. 4 decades . Description: The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research. Unparalleled performance on a personalized platform. These models can no longer be repaired. SpectraMax iD5 Multi-Mode Microplate Reader (Molecular Devices cat. Description Bottom Volume Qty/Pk Qty/Cs 3635 96 Well UV-Plate Flat 370 µL 2550per well of this semi-solid mixture was pipetted into 6-well plates. Resipher 96x Starter Kit for use with 96-well plates Includes: (1) Resipher Data Hub, (1) Resipher 96x Reader, (3) sterile sensing lids, all cables Turns a 96-well plate into a precise dynamic oxygen consumption reader, measures 96 wells Utilizes Lucid Lab Cloud software for connection to any…. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384. #23225). Corning. Note: if all wells of a 384-well plate are to be read, the kinetic interval may need to be. #6590-0137) Optimal instrument settings for ValitaTiter (P/N VAL003 or VAL013, left table) and ValitaTiter Plus (P/N VAL004 or VAL014, right table) assays on the SpectraMax iD5 reader are shown below. Specialized filters allow for IR fluorescence detection ranging from 10-40 times more sensitive than conventional monochromator detection reader. p-Nitroaniline - Catalog No. x. This can increase throughput and efficiency, thus saving time and space in the lab. 00 Add to cart; Molecular Devices EMax Microplate Reader $. ©2022 Molecular Devices - All rights. Molecular Devices. x. It has a 340-750nm Spectral Range. Enter the name of the plate type i. Our multi-mode plate readers provide great flexibility and include absorbance, fluorescence and luminescence with configurable options for fluorescence polarization (FP), time-resolved fluorescence (TRF), FRET, and AlphaScreen. #C1500) Control standard endotoxin (ACC cat. 000 to 2. This study investigated the efficacy of fermented seaweed (Eucheuma cottonii) on the remediation of fluoride-contaminated soil. Detection of KASP genotyping reactions. Users can choose to process all plates within the magazine or select a specific number. #iD5-STD). Top reading gives greater sensitivity for 96 well plates, unless you have cells adhering to the bottom of the well. 5039228D 3 Contents SafetyInformation 5 Warnings,Cautions,Notes,andTips 5 Chapter1:Introduction 11 ComputerIntegration 12 Applications 12 Optics 13 PlateControls 13The microplate reader has been around for more than three decades and continues to serve as a must-have workhorse of clinical, academic research and industrial laboratories alike. Loading Buffer was also added to a set of cell-free wells for background controls. 0% ± 0. Plate readers, also known as microplate readers or microplate photometers, are instruments which are used to detect biological, chemical or physical events of samples in microtiter plates. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. This reader can also be used as a standard. 5 µL of each sample was pipetted into a 96-well plate for PCR. SpectraDrop Micro-Volume Refills, 24-Well Bottom Slides. Plates were read in the SpectraMax M5 microplate reader at 485ex/515em with bottom read. The patented quench technology is offered to drug discovery and life science researchers exclusively by Molecular Devices, through the purchase of FLIPR Assay Kits. 1 fmol luciferase per well. CO 2 & O 2 control. This can increase throughput and efficiency, thus saving time and space in the lab. 200, the Bio-Tek µQuant™, the Bio-Rad UltraMark™, the Molecular Devices SPECTRAmax® 190 and 250 plate readers. : 2 Oct 12 Page 1 of 20 Setup Guide on the Molecular Devices SpectraMax® Paradigm® Microplate Detection Platform Have a question? Contact our Technical Support Team NA: 800-955-6288 or INTL: 760-603-7200 ext. This 96-well assay has been fully validated on the SpectraMax iD5 reader and other Molecular Devices microplate readers with FP detection to ensure reliable results. Before dispensing reagents to the microplate, the VersaMax Reader was powered on and SoftMax Pro GxP. Polypropylene deep well plates, round bottom. The VICTOR Nivo. For the 96-well plate, this equates to 1 fg per well to 1 ng per well; for the 384-well plate it is 0. Powerful, benchtop microplate stacker that works seamlessly with Molecular Devices microplate readers and washers. Supplier: Molecular Devices Next generation SpectraMax® absorbance microplate readers. 96-well plate: 0 to 4 Abs, ±2% at 450 nm, 384-well plate: 0 to 3 Abs ±2% at 450 nm: Measurement Type: Endpoint, Kinetic, Spectra, Multipoint, Kinetic Spectra: No. Multimodal plate reader: Yes: 25 mm: Yes—Max. 000 – 4. Compare Tool. 10 µL of BSA standard or cell lysate was pipetted into wells of a 96-well microplate (n = 3). 96- and 384-well microplates. Learn more. A polyclonal antibody specific to mouse/rat IL-22 was pre-coated onto a 96-well microplate. Versa Max. Elevated well walls for easier sealing Round bottom formats Square and round well formats Conform to SBS standards Lids and cap mats available Packed in sleeves of 6, 24. Optional 12-way manifold) 5032336. When a. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a. Published Dec 16, 2020 | Updated Dec 06, 2021. x. Validation made easy -1) Select the correct plate and the wells that you want to measure. 300 µL of Detergent Compatible Bradford reagent was added to each well. This approach enables uniform light dose application to 9 wells (a 3-by-3 matrix in a 96-well plate) simultaneously, which can be leveraged to shorten the duration of PDT experiments (Fig. Read the microplate • Make sure the purple plate adapter (if required for your plate reader) is in the microplate reader drawer. robotics-automation-compatible. Plate Shaking. All readings were taken in clear, polystyrene 96-shallow-well, flat-bottom plates. Each plate reader or washer is calibrated, inspected, and lubricated—any potential issues . They are also sealable using different types of adhesive mats foils or films. This instrument is ideal for measuring dual luciferase assays in both 96- and 384-well plates, and SoftMax Pro® software simplifies data collection and analysis with preconfigured protocols. Compare this item. Related Products: 96 Well Plate Reader. 00. 40266. Category 2 and 3 microplate readers use gradient heating as well. #3693; n = 4 for each standard). Upgradeable modules are also available including western blot, cell imaging, and fast kinetics with injectors. UV Plate 96 Well, Flat Bottom, Cs 50. 96-, 384-, and 1536-well microplates. The picked. Both reactions can be easily measured in Molecular Devices’ new SpectraMax® L microplate luminometer. Erik Koppes, Richard Haas, Jerry Vockley, Lina Ghaloul-Gonzalez approximately 5,000 cells were seeded in 4 replicates in 96-well plates. Service parts for these models are not being produced and are no longer in stock. Conventional technique: subjective, time-consuming. Determine concentration using the Beer-Lambert LawPage 1 ™ VERSAmax Tunable Microplate Reader Operator’s Manual for Instruments with Serial Numbers Beginning with BN Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0084 Rev. The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax ® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. HepG2 cells were plated into a 96-well clear-bottom, white-walled plate at 10,000 cells/well and incubated at 37°C overnight. The SpectraMax M4 Microplate Reader is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96 and 384-well microplates. Figure 2. The top- and bottom-reading Gemini EM Microplate. 1 x plates; Instrument dimensions. The soil was amended with either 1. Molecular Devices' microplate readers. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). Selects either 96-well or 384-well plate for a stand-alone read. 00. This chapter reviews key criteria for microplate selection, including: well number, well volume and shape,. To maximize sensitivity of the assay, it is necessary to use optimal excitation and emission wavelengths. The CellTiter-Glo assay was used to measure ATP. to each well. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. A preconfigured protocol with optimized reader settings enabled reading of a 384-well plate in just two minutes. 5 fg per well to 0. The color touch screen provides a visual user interface, making programming fast and intuitive. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. x. Expand Microplates and select the newly created plate. • High antibody-binding surface improves the overall performance in. Transfer the assay plate directly to a bottom-read fluorescence microplate reader for kinetic read-mode or incubate for 10-30 min at 37oC and then read for endpoint read-mode. as well as all other Molecular Devices' microplate readers. For measuring the fluorescence or phosphorescence from a 6-, 12-,24-, 48-, or 96-well plate in either the X or Y direction or for luminescence micro densitometry of TLC plates and electrophoresis gels. No accessories are needed and SoftMax® Pro Software. NOTE: Limited support and literature is available for the SpectraMax 250 due to the senescence of the product. Plate Storage Solutions for Liquid Handling Automation Remote Lab Management. 20 µL (96-well plates) or 10 µL (384. 315 can't find zero order. Bay Gray powder coated metal back plate, column, and base. 2 pM 384–well: 3 pM 96–well: 2 pM 384–well: 4 pM 1 0200-7012POS Glow for 96-, 384-, and 1536-well plates Here, we demonstrate that with Molecular Devices SpectraMax® microplate readers and the Quant-iT PicoGreen assay, users can reliably measure concentrations as low as 50 pg/mL of double-stranded DNA. 1. These plasticware can come in a variety of formats, such as skirted, semi-skirted, unskirted, clear, colored, and barcoded. Order Now. minutes and begin reading microplates with seven mouse clicks. Read the plate on the SpectraMax M5, M5e, or FlexStation 3 reader using the optimized settings shown above. A Costar 24-well tissue culture plate with col1 = blanks and doubling cell a list of plates specifically supported shows, 96, 384, 24, 12, 6 well types. An industry-renowned instrument for monitoring GPCRs and ion channels. The wavelength and scanning ranges are from 340–850 nm in 1 nm increments. SpectraMax 340PC384 Microplate Reader A versatile 96- and 384-well format absorbance reader let the monochromator tune to that exact wavelength. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. µl) was added to each well and incubated at 37°C for 1 h. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384. With various on-board features and capabilities, the ThermoMax. Place the microplate in the drawer. The SpectraMax ABS readers can be integrated with Molecular Devices StakMax® Microplate Stacker within . The Absorbance 96 Plate Reader is designed to run everyday assays with ease and speed. Step 3: Click “Settings” and a screen will appear (Figure 1). 9. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. Usage/Application: Lab. and California)The upgradeable SpectraMax M5 Multi-Mode Microplate Reader comes with the standard five modes of detection with the upgrade option to add HTRF at a later time. 1 mL/well of media. Molecular Devices delivers a robust screening platform to address real-time kinetic cell-based assays with the FLIPR Tetra® System. The 8-channel read head allows for fast read times which means a 96-well plate can be read in as little as five seconds. ₹ 1,80,000 Get Latest Price. Published Dec 16, 2020 | Updated Dec 16, 2020. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Microplate readers from Tecan; cutting edge bench-top microplate readers lead the industry in both versatility and performance. The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular biology and immunoassays. the Gemini XPS reader. The StakMax stacker also allows users to feed plates into the loading area manually. Now select the area of the plate to read. SpectraTest FL1 Fluorescence Validation Plate User Guide Molecular DevicesData are shown as the mean ± s. The SpectraMax L reader is easily integrated with the optional StakMax microplate stacker from Molecular Devices for automated multiplate assays. The SpectraMax Quant dsDNA Assay Kits provide pre-optimized, complete solutions that are sensitive, accurate, and easy to use. Reaction formats The MagMAX™-96 DNA Multi-Sample Kit can accommodate a broad range of throughputs. Recertification service. The BCA assay plate was read at 562 nm, the original wavelength setting in the protocol, while for the BCA Rapid. Locate the User Guide on your SoftMax Pro computer for version 6 and version 7. S. From the Windows Start menu, go to All programs > Molecular Devices > SoftMax Pro x. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). Its software interface is easy to learn and use, and lets you control the instrument from almost any device – perfect for. Whether running fluorescence imaging or brightfield assays, the automated imager features a comprehensive portfolio of preconfigured protocols for cell-based assays to shorten the learning curve, so. Therefore you need to ask a physicist. AlphaScreen and AlphaLisa detection using a 680 nm excitation laser diode and a 570/100 nm emission filter. #25-340) Pyrogen-free Dilution Tubes (Lonza cat. 6. Supplier: Molecular Devices. For the kinetic and endpoint LAL assays, the ELx808 TM Reader is highly reliable and easy to use. Select up to 3 products. Instrument pricing. 00 . x. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. Resipher 96x Starter Kit for use with 96-well plates Includes: (1) Resipher Data Hub, (1) Resipher 96x Reader, (3) sterile sensing lids, all cables Turns a 96-well plate into a precise dynamic oxygen consumption reader, measures 96 wells Utilizes Lucid Lab Cloud software for connection to any…. 5032338. Bioz Stars score: 86/100, based on 40 PubMed citations. 96 wells 384 wells 1 pM 1 pM Optimized bottom sensitivity (fluorescein) 96 wells 384 wells 2 pM 2. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. No tools required to assemble. Applications include ELISA, protein quantification, enzyme kinetics and cell-based assays. Download a PDF version of the SpectraTest validation package User Guide and the ABS2 SpectraTest validation protocols. Measurements for every well are automatically tracked over time. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. The opaque walls prevent stray light from being detected from neighbouring. • Remove media from each well using a blue pipette tip being careful as not to remove cells. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). VMax . 5. The following detection cartridge is required: • Fluorescence Polarization (FP-FLUO) Detection Cartridge. SpectraDrop High-Throughput Screening (HTS) Kit. It features a modular design that allows users to add or change detection cartridges according to their needs. Absorbance Detection Cartridges combine scanning and broad spectrum wavelength range to address a variety of nucleic acids, proteins, ELISAs and immunoassays found in the laboratory. 046 to 0. 500 USD. Based on this customer experience and feedback, the Infinite 200 PRO microplate plate reader has been continuously engineered for. It offers extremely low absorbance background, excellent. x. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics. g. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. A Costar® 24-well tissue culture plate with col1 = blanks and doubling cell concentration left to right starting at Col. Supported Plates Microplates having 6, 12, 24, 48, 96, and 384 wells can be used in the SpectraMax Multi-Mode Microplate Readers. Mix well by trituration or plate shaker and incubate for 2 to 5 minutes at room temperature, protected from light. SoftMax Pro GxP, together with a Molecular Devices plate reader and Molecular Devices GxP Admin software, provides a fully integrated hardware and software solution forThis UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. Two different agonists, acetylcholine and carbachol, were tested. Two different agonists, acetylcholine and carbachol, were tested. 20 attomol ATP per well. Linear, Orbital Slow, and Orbital Fast. Microplate spectrophotometers, also called microplate readers, allow researchers to analyze multiple samples in parallel using 6- to 1536-well formats, as opposed to single sample measurements. D. The AquaMax® Microplate Washer is a fully self-contained system, configurable for both 96- and 384-well microplates. Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Cross-talk <0. A. REF (SpectraMax. These plates are compatible with standard fluorescence microplate readers and are offered in a. White light and fluorescence images of the 6-well plates were captured with the ClonePix 2 System. Consequently, FLIPR has been used. is required for optimum performa nce with standard 96-well and 384-well format microplates for all top-read applications. Materials. Accurate, efficient nucleic acid quantitation is critical for molecular biology labs that work with precious, rare, or difficult-to-process samples and applications requiring precise measurement. Through absorbance readings from both the ultraviolet and visible spectrum range, it can determine the concentration of samples, conduct positive or negative detection of antibodies and. #R8195. 25% and 0. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. 1. Published Dec 16,. Transfer the assay plate directly to a bottom-read fluorescence microplate reader for kinetic read-mode or incubate for 10-30 min at 37oC and then read for endpoint read-mode. x. When samples are added to the wells, the Protein G molecules are resuspended and binding occurs. perfect for kinetic readings involving growth curves at 5 seconds per plate. PURPOSE. Z. 0, or. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide — 0112-0102 Rev. The microplate (containing standards) was incubated at 37ºC in the preheated SpectraMax ABS Plus reader for 10 minutes. Find our technical support information along with contact details. Temperature variation ± 0. Published Dec 16, 2020 | Updated Dec 16, 2020. After incubation of the cells with compounds, add 100 µL (for 96-well plates) or 25 µL (for 384-well plates) of Dye Solution per test well. 96-well PCR plates are plastic, heat-resistant multi-well microplates designed for use inside PCR machines or real-time (qPCR) thermocyclers. Use form “26003-02: Molecular Devices Plate Reader Plate Calibration Form” to record material and equipment information. Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. Microplate Spectrophotometers. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. plate loading adapter and a choice of magazines for 20, 40 or 50 SBS-standard 96- and 384-well microplates. Make sure toPlate reader instructions Computer. 020 fmol 0. UV-Star ® 96W Microplate, well working volume 25-370 μL; total well volume 392 μL. Figure 1-2 Match chamfered corners of slide and adapter 2. 030 fmol Fluorescence Polarization (FP). Temperature control range from Ambient +4º to 50ºC. The EMax Endpoint ELISA Microplate Reader from Molecular Devices (one of the pioneers of microplate detection) provides a simple and durable dedicated endpoint detection method. You can use 6, 12, 24, 48, 96, and 384-well plates that conform to ANSI/SBS standard microplate footprint and dimensions in the instrument. A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among others. Microplate Readers include the M3, M4, M5, and M5e models. The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. We would like to show you a description here but the site won’t allow us. x. Fireflysci UV/VIS Fluorescence Validation Plate for Well Plate Reader (290-562nm) FLVP-01. 4ti-0255 96 well assay plate, pyramid flat bottom, clear, non-sterile UV wavelength 4ti-0214 UltraVision Plate 384, black, non -sterile, with UV baseELISA Workflow Using the EMax plus Microplate Reader and MultiWash+ Microplate Washer. 1. Get Quote . 000 OD ± 1. Capabilities. Supported Plates Microplates having 6, 12, 24, 48, 96, and 384 wells can be used in the SpectraMax Multi-Mode Microplate Readers. #N207) LAL Reagent Water (Lonza cat. 46Click the Read button in the SoftMax Pro3 reader combines Molecular Devices SpectraMax® M5e Multi-Mode Microplate Reader performance with an integrated 8- or 16-channel pipettor into one compact. The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. 993 (Figure 3), validating the assay’s usefulness over a wide range of viable cell numbers. to each well. 0025 OD from 0. Plate and Setup Rack Options Screens with selection of up to four Methods shown. Both reactions can be easily measured in Molecular Devices’ new SpectraMax® L microplate luminometer. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics. The reader measures both flat and round 96-well microplates and ensures accuracy by automatic lamp calibration prior to. SpectraMax 340PC384 Microplate Reader A versatile 96- and 384-well format absorbance reader let the monochromator tune to that exact wavelength. VIS absorbance detection. Microplate Readers include the M3, M4, M5, and M5e models. UT-6550 Microplate Reader is a reliable and robust instrument for a wide. You should ensure that there is enough volume in compound plate wells to operate the IonWorks® system taking into account the dead volume. and California) Microplate Spectrophotometer 100-240V ~ 4A 50-60 HZ T4. Powered by a new, optional high-speed EMCCD camera and the new Peak Pro 2 software module, the new FLIPR® Penta High-Throughput Cellular Screening System allows you to measure and analyze peaks of human-derived induced pluripotent stem cells (hiPSCs),. Figure 3. Mix samples in microplate wells by user-programmable Automix feature. It is designed to work seamlessly with a variety of 96 well microplate readers, including popular brands such as Agilent™, Berthold™, Biotek™, BMG LABTECH™, Molecular Devices™, Perkin Elmer™, Promega™, Tecan™, and. Upon completion of a plate read, data are delivered to your computer in an Excel-compatible format. Self-righting base, up to 40 degrees past center without dispenser. Contact our support team with your questions regarding Molecular Devices products and applications. SpectraMax iD5 Multi-Mode Microplate Reader (Molecular Devices cat. This is equivalent to having 511 built-in filters, The instruments offer 96- and 384-well microplate-to-microplate fluid transfer (8 or 16 wells at a time), and can read microplates having 6, 12, 24, 48, 96, and 384-well formats. Compare. Because many reagents can be fluorescently labeled, spectrofluorometers are used to detect many biological and chemical processes. UV cuvettes are ideally suited for measurements at 260 nm, 280 nm and in the visible range. Devices® SPECTRAmax 190 microplate reader at a wavelength of 600 nm. M2. Description. UV Plate 96 Well, Flat Bottom, Cs 50. Chirag Patel, a graduate student at Johns Hopkins, reviewed Molecular Devices' SpectraMax M5 Multi-Mode Microplate Reader and found it an excellent resource for his lab's research on mTOR signaling in CD8 T cells. SoftMax Pro GxP Software version 5. Quickly image a variety of plate formats and cell types - Image a 96-well plate in under two minutes. softmax pro software, gemini em reader, molecular devices stakmax microplate stacker, softmax pro data analysis, spectrofluorometer, monochromator microplate reader, cell migration assays, cell. TNF standard curve. With the novel filter system, assays such as hydrogen peroxide detection assays and IRantibody-binding assays can be run confidently with Molecular Devices set of0112-0115J 9 Chapter1:Introduction TheSpectraMax®M3Multi-ModeMicroplateReader,SpectraMax®M4Multi-ModeMicroplate Reader,SpectraMax®M5Multi-ModeMicroplateReader,andSpectraMax®M5eMulti-ModeMolecular Probes® 96-well microplates for fluorescence-based assays are black-walled, clear-bottom 96-well microplates that minimize well-to-well crosstalk and autofluorescence and so are optimized for fluorescence-based applications. Products : SpectraTest Validation Plates ABS2, SpectraTest Validation Plates ABS1, SpectraTest Validation Plates FL1, SpectraTest Validation Plates LM1. Two high-energy xenon flash lamps: Reading capabilities. Three kits covering a wide range of dsDNA concentrations.